Specifications | ||
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) | |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) | |
Chassis height [U] | 1 U | |
Weight without packaging [kg(lb)] | 2.9 kg (6.39 lb) | |
Weight with packaging [kg(lb)] | 3.55 kg (7.83 lb) | |
Typical power consumption [W] | 32.6 W | |
Maximum power consumption [W] | 41.7 W | |
Static power consumption [W] | 17.57 W | |
Noise at normal temperature (acoustic power) [dB(A)] | 38.1 dB(A) | |
Noise at normal temperature (acoustic pressure) [dB(A)] | 26.1 dB(A) | |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. | |
Packet forwarding rate | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. | |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) | |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). | |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) | |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) | |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | |
Power supply mode | AC built-in | |
Rated input voltage [V] | •AC input: 100 V AC to 240 V AC; 50/60 Hz •High-voltage DC input: 110 V DC to 250 V DC | |
Input voltage range [V] | •AC input: 90 V AC to 264 V AC; 47 Hz to 63 Hz •High-voltage DC input: 88 V DC to 300 V DC | |
Power supply surge protection [kV] | Differential mode: ±6 kV; common mode: ±6 kV | |
Console port | RJ45 | |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment | |
Airflow direction | Air intake from left and front, air exhaustion from right | |
Certification | EMC certification Safety certB1:C27ification Manufacturing certification |
info@signaux.ae
+971 455 399 46
+971 508 598 606
SIGNAUX Technologies LLC, P O BOX 390667, #614, Detroit House, Motor City, DUBAI, UAE
© 2025 SIGNAUX. All rights reserved.