Specifications | ||
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) | |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) | |
Chassis height [U] | 1 | |
Installation type | Rack mounting,Desk mounting,Wall mounting | |
Chassis material | Metal | |
Weight without packaging [kg(lb)] | 2.71 (5.97) | |
Weight with packaging [kg(lb)] | 3.59 (7.91) | |
Typical power consumption [W] | 36.95 | |
Maximum power consumption [W] | 44.3 | |
Static power consumption [W] | 18.8 | |
100% power consumption [W] | 36.95 | |
Number of fans modules | 1 | |
Maximum number of physical ports on the entire device | 52 | |
Maximum number of GE ports | 52 | |
Maximum number of FE ports | 48 | |
Uplink ports | 4 x 10GE SFP+ ports | |
Downlink ports | 48 x 10/100/1000BASE-T ports | |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) | |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used. The device does not support dying gasp when the ambient temperature is higher than 40°C (104°F). | |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) | |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) | |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | |
Power supply mode | AC built-in | |
Rated input voltage [V] | AC input: 100–240 V AC; 50/60 Hz | |
Input voltage range [V] | AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz | |
Maximum input current [A] | 1.6 A | |
Console port | RJ45 | |
Service port surge protection [kV] | Common mode: ±7 kV | |
Power supply surge protection [kV] | Differential mode: ±6 kV; common mode: ±6 kV | |
Types of fans | Built-in | |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment | |
Airflow direction | Air intake from left and air exhaust from right | |
Certification | EMC certification Safety certification Manufacturing certification |